国产风流老太婆大bbbhd视频,熟女肥臀白浆大屁股一区二区,久久偷看各类wc女厕嘘嘘,特级做a爰片毛片免费看

全國服務(wù)咨詢熱線:

15618996225

當(dāng)前位置:首頁  >  產(chǎn)品中心  >  太赫茲  >  太赫茲功率計(jì)  >  Mm-Wave power meter高靈敏度毫米波功率計(jì)

高靈敏度毫米波功率計(jì)

簡要描述:高靈敏度毫米波功率計(jì)Features
0.01-220 GHz operating frequency
High sensitivity
Up to 55 dB dynamic range (0.1uW-30mW)
Small measuring time (< 1 sec)
RS-232, GPIB interface
SCPI protocol

  • 產(chǎn)品型號(hào):Mm-Wave power meter
  • 更新時(shí)間:2024-09-02
  • 訪  問  量:773

產(chǎn)品簡介

品牌其他品牌產(chǎn)地類別進(jìn)口
應(yīng)用領(lǐng)域農(nóng)業(yè),電子,汽車,電氣

詳細(xì)介紹

 

高靈敏度毫米波功率計(jì)Features  
  • 0.01-220 GHz operating frequency

  • High sensitivity

  • Up to 55 dB dynamic range (0.1uW-30mW)

  • Small measuring time (< 1 sec)

  • RS-232, GPIB interface

  • SCPI protocol

高靈敏度毫米波功率計(jì)Applications  
  • Recommended for use by Rohde & Schwarz

  • Measurements of power level of mm-wave signal

  • Test equipment

Description

The DPM-xx is a single-channel average power meter for RF to millimeter wave frequencies that measures absolute power from 10 MHz to 220 GHz.

DPM-xx Power Meters display measured power in milliWatts, microWatts or dBm, and also display the user-entered signal frequency in GHz. Easy operation is ensured with automatic zeroing, automatic sensor recognition and a calculation factor table stored in the memory of each power sensor.

Their compact size, precise accuracy, reliability and inexpensive pricing make our DPM-xx Power Meters attractive assets for design engineering, equipment manufacturing, field engineering and research.

ELVA-1’s ZBD-series Zero-Biased Detectors are used as the power sensors for our DPM Power Meters.To cover the range from 10MHz to 220GHz band, we offer one coaxial (10 MHz-26.5 GHz) and 9 waveguide power sensors (26.5-220 GHz in waveguide bands), sold separay.

Based on Schottky Barrier Diode technology, our ZBD power sensors provide high sensitivity, fast measurement speed and quick response to changes of input power. To extend the dynamic range of diode power sensors above their square law region, a correction factor is used. The amplitude and frequency curves for each individually-calibrated power sensor are stored in the sensor’s EEPROM. When a sensor is connected to a DPM control/display unit, the control/display unit automatically recognizes that sensor’s characteristics. The typical curves for amplitude and frequency transfer characteristics at W-band are shown on the reverse.

Measured average power is displayed on a 2-line LCD screen, at a measurement rate of 2 times per second or faster. For power measurements below 10-100mW (depending on frequency band), each sensor is supplied with a full-band isolator. For power measurements above those levels (as high as 300mW-1Watt), optional directional couplers are available.

Every DPM-xx is equipped with an RS-232 port for control and measurement data exchange with a PC. An internal GPIB interface board is available as an added option. On special request we can also provide a dual channel power meter of DPMD-XX series with two independent measurement channels.

Since the control/display unit and power sensors are sold separay, customers only need one DPM control/display unit to interface with all 10 of our sensors. To obtain power measurements over a multi-waveguide frequency range, order one DPM control/display unit and several adjacent-band sensors.  Because the standard ELVA-1 DPM control/display unit is a single-channel meter, only one power sensor can be used at one time.

 

DPM-XX Key Features and Specifications

- Display readings: milliWatts, microWatts or dBm

- Maximum measuring rate: up to 50 times per second, default 2 times per second (set at factory)

- Frequency Range: 10 MHz to 220 GHz

- Min. measured Power: 0.1 microWatt (depending on frequency band)

- Dynamic Measurement Range: 55dB max. (depending on frequency band)

- Frequency step: 10 MHz

- SCPI or ELVA’s command protocol

- RS-232, GPIB interface

- Calibration accuracy ±0.04 dB (log) or ±1%

- Power Sensor Calibration: Individually calibrated, with amplitude and frequency curves in flash memory

- If a valid signal frequency is not entered before measuring power, maximum measurement error will be ±1.5dB for Ka, Q, U, V bands, ±2.0dB for E, W bands, and ±2.5dB for F, D bands, based on calibration curve flatness.

Model Number DPM-C DPM -28 DPM -22 DPM -19 DPM -15 DPM -12 DPM -10 DPM -08 DPM -06 DPM -05
Frequency Band Ka Q U V E W F D G
Frequency Range, GHz 0.01-26.5 14757 33-50 40-60 50-75 60-90 75-110 90-140 110-170 140-220
Input Waveguide/Impedance 50 Ohm, Coaxial WR-28 WR-22 WR-19 WR-15 WR-12 WR-10 WR-08 WR-06 WR-05
Wavequide Flange/Connector SMA, male UG-599/U UG-383/U UG-383/U-M UG-385/U UG-387/U UG-387/U-M UG-387/U-M UG-387/U-M UG-387/U-M
Dynamic Range, dB (max) 50 55 55 55 55 55 55 55 50 40
Min Measured Power Level, dBm -33 -43 -43 -43 -43 -43 -40 -40 -35 -25
Measurement Rate (default), times per sec 2 2 2 2 2 2 2 2 2 2
VSWR (power sensor) 1.2:1 1.3:1 1.3:1 1.3:1 1.3:1 1.4:1 1.4:1 1.4:1 1.4:1 1.4:1

Available operating power options: 220 VAC, 110/100 VAC, or battery power (for portable version).

 

產(chǎn)品咨詢

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細(xì)地址:

  • 補(bǔ)充說明:

  • 驗(yàn)證碼:

    請輸入計(jì)算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7

全國統(tǒng)一服務(wù)電話

021-62209657

電子郵箱:sales@eachwave.com

公司地址:上海市閔行區(qū)劍川路955號(hào)707-709室

業(yè)務(wù)咨詢微信

色五月丁香六月欧美综合| 伊人久久大香线蕉AV一区| 老师的粉嫩小又紧水又多a片| 亚洲va久久久噜噜噜久久狠狠| 精品久久久久久久换人妻| 精品人妻无码专区在中文字幕| 国产精品久久久久av福利动漫| 激情综合色综合啪啪开心| 艳妇荡女欲乱a片在线观看| 搡老熟女国产| 天堂资源官网在线资源| 色戒汤唯未删减版的在线观看| 日韩国产丝袜人妻一二区| 中国少妇videos露脸hd| g奶大爆乳交在线观看theav| 欧美一区二区三区视频在线观看| 淑娟两腿间又痒了| 欧美猛少妇色xxxxx| 男人亚洲成色av网站| 久久久久久久久久久精品| 精品国产不卡一区二区三区| 后入式动态图| 制服 小说 亚洲 欧美 校园| h漫无码动漫av动漫在线播放| av无码精品一区二区三区四区| 丁香激情综合久久伊人久久| 久久久久噜噜噜亚洲熟女综合| 国产欧美亚洲精品a| 亚洲无AV码一区二区三区| 九九视频在线观看视频6| 亚洲av区无码字幕中文色| 69堂国产成人精品视频| 人人爽久久久噜噜噜婷婷| 亚洲 欧美 中文 日韩| 国产免费av| 日日碰狠狠躁久久躁| 无码人妻精品一区二区蜜桃在线看 | 午夜亚洲国产理论片2020| 97超级碰碰碰免费公开在线观看| 午夜亚洲av永久无码精品| 又粗又黄又爽视频免费看|